Pool turnover rate calculator
Turnover is how long your pump takes to push one pool's worth of water through the filter. It is a division: gallons ÷ (gallons per minute × 60). Enter a volume and a flow for the hours, or a volume and a target turnover for the flow you need.
Result
turnovers per day = 24 ÷ turnover hours
gpm needed = gallons ÷ (target hours × 60)
rectangular gallons = length × width × average depth × 7.48052
round gallons = π × (diameter ÷ 2)² × average depth × 7.48052
What a turnover figure does and does not settle
One turnover does not mean every drop has been filtered. Filtered water mixes back into the pool, so after one turnover a well-mixed pool has had roughly 63% of its water through the filter, and it takes about three turnovers to reach 95%. That is the nature of mixing, not a defect in the pump. It is also why turnover targets are rules of thumb rather than a hygiene guarantee.
How many turnovers a day your pool needs is a local question. Health departments set the requirement for public pools, and the figures vary by jurisdiction and pool type; residential pools are generally not covered by those rules at all. This calculator therefore does not tell you a target — it converts between volume, flow and hours so you can apply whatever requirement or habit you are working to. If you want a defensible number for a public or semi-public pool, the requirement in your state or county's pool code is the only one that counts.
Two practical consequences. First, running longer at a lower speed can deliver the same turnover for far less energy, because power falls much faster than flow when speed drops — that is the whole case for a variable-speed pump, and you can price it in the cost calculator. Second, flow is capped by your plumbing, not only by the pump: pipe diameter, fittings and filter condition set the head the pump works against, and oversizing the pump against narrow pipe buys noise and wear rather than turnover.
Related
Once you know the flow you need, find a certified record that measures near it. The flow figures in the dropdown come straight from each record's test points, and each record has a page: the Hayward TriStar VS measured 25.19 gpm at its low-speed point and 48.44 gpm at its high-speed point, the Pentair IntelliFlo VS and the Jandy VS FloPro publish their own pair, and the full set is grouped by maker on the Hayward, Pentair and Jandy hubs.
Then price the schedule with the pool pump energy cost calculator, which can hold two pumps against the same hours and electricity rate, or read how the weighted energy factor folds flow and power into one number.